International Journal of Ophthalmic PathologyISSN: 2324-8599

All submissions of the EM system will be redirected to Online Manuscript Submission System. Authors are requested to submit articles directly to Online Manuscript Submission System of respective journal.

Lower order aberrations and contact lenses: A rationale for 0.50DC toric soft lenses


Kenneth R Seger

Nova Southeastern University College of Optometry, USA

: Int J Ophthalmic Pathol

Abstract


Purpose: Lower order aberrations have been correctable for generations; defocus for hundreds of years and an astigmatism for over a century. For the last several years there has been considerable interest in correcting higher order aberrations (HOA). However, as of now, toric soft lenses, which have become so reliable that they are manufactured as daily disposables, have 0.75DC as their lowest cylindrical correction. This leaves many patients with an uncorrected cylindrical component which causes a greater negative impact of vision than typical uncorrected HOA values. Is there a need or justification for manufacturing -0.50DC toric lenses? Methods: The data of all spectacle lens prescriptions for three consecutive months was obtained from an independent spectacle lens fabrication laboratory. The cylindrical component powers were tabulated and analyzed. The number of current toric lens combinations and additional lens combinations necessary for 0.50DC correction was calculated. Results: Out of 3869 consecutive spectacle lens prescriptions, 778 (20.1%) had correction of -0.50DC (27.3% of all cylindrical corrections), suggesting that 20% of potential lens wearers have significant residual astigmatism. Using the parameters of sphere power of +6.00 to -8.00 (in 0.25D steps) with cylindrical corrections of 0.75, 1.25, 1.75 and 2.25 DC in round the clock axis steps of every 10 degrees 3816 lens alternatives need to be available. To incorporate -0.50DC correction an additional 934 lens parameters (an increase of 24.5%) would be necessary. Conclusions: Increasing the toric lens inventory by ~25% would theoretically capture an additional 20% of currently lessthan- optimally corrected potential contact lens wearers. We suggest contact lens manufacturers, in addition to pursuing HOA correction, might more profitably work on developing a 0.50DC toric lens.

Biography


Kenneth R Seger (OD, MSc, FAAO) has been on the faculty at Nova Southeastern University College of Optometry for 18 years. Prior to that he spent six years in private practice in his hometown, San Luis Obispo, CA followed by 16 years as part-time clinical faculty at the University of California Berkeley School of Optometry. At NSUCO, her has pursued research interests in contact lenses, myopia development and (with Dr. Ava Bittner) a unique treatment modality for RP.

Track Your Manuscript

Awards Nomination

GET THE APP